Product Engineering - Quality Management
How To : Setup Quality Management
Besides the quality management setup, as mentioned below, the following is required to have measurements created automatically:
- QM Subscribers: to specify WHEN to measure
- Note: In most cases the QM Subscribers list will be populated automatically. If not use the Initialize QM Subscribers action on the QM Subscribers page.
- Measurement Template: to specify HOW to measure specifying:
- The table from which the measurement is triggered (as enabled in the QM Subscribers)
- The sampling method
- Questions and a question set to create check sheets
- User defined fields
- Check sheet rating
- Target Template to specify WHAT to measure
Quality Management Setup
- Choose the icon (Alt+Q)
- Type Quality Management Setup:
Field | Description |
---|---|
General fast-tab | |
Default Due Date Formula | The time allowed to complete a check sheet |
Automatic create Measurements | When checked Measurements will be created automatically when a Measurement Template is found by the Incident |
Post with Job Queue | When checked Measurements will not be created immediately, instead a Job Queue entry will be created. |
Quality Team Code | To-Do's created from the Measurement will be assigned to this team code. |
Default Quarantine Location | Select the location where rejected items have to be moved to as one of the Registered Measurement follow-ups |
Quarantine Journal Template Name | Select the re-classification template to be used for moving rejected items to the quarantine location |
Quarantine Journal Batch | Select the batch name for the re-classification journal to be used for moving rejected items to the quarantine location |
Numbering fast-tab | |
Measurement Nos. | Specify the number series to be used for the measurements |
Check Sheet Nos. | Specify the number series to be used for the check sheets |
Registered Measurement Nos. | Specify the number series to be used for the registered measurements |
Captions fast-tab | |
Captions UDF 1..10 | Specify the captions for the user defined fields to be used for the measurements |
Notifications
To show a message in the source document when a measurement is created you have to set the notification:
- Choose the icon (Alt+Q)
- Type My Notifications an choose the link
- In the My Notifications page locate: Show Incident Notification and make sure Enabled is true.
See also
Feedback
Submit feedback for